Radial head replacement with a bone cement spacer

Authors

Keywords:

fracture, forearm, spacer, bone cement

Abstract

Introduction: Forearm fractures are usually secondary injuries to high-energy trauma. They can affect the radius, ulna, or interosseous membrane.

Objective: To evaluate the bone cement spacer technique for radial head replacement in an Essex-Lopresti fracture dislocation of the forearm.

Case report: This patient presented with an Essex-Lopresti fracture dislocation of his right forearm. The radial head was replaced using a bone cement spacer technique, with a surgical time of approximately one hour and 20 minutes. Healing of the interosseous membrane and triangular fibrocartilage of the distal radioulnar joint of the right wrist was achieved at six weeks. The spacer prosthesis was then removed.

Conclusions: Radial dome replacement using a bone cement spacer technique for an Essex-Lopresti fracture dislocation of the right forearm was successful.

Downloads

Download data is not yet available.

Author Biography

Alejandro Gómez Sarduy, Hospital Mártires del 9 de Abril, Sagua la Grande.

Especialista en Primer Grado de Ortopedia y Traumatología

References

1. Bitar EM, Gaviria S, León N, Gallego S. Epidemiología del trauma de miembro superior atendido en seis instituciones de salud de la ciudad de Medellín, Colombia, en 2016. Cir Plást Iberolatinoam. 2021;47(3):323-32. DOI: https://dx.doi.org/10.4321/s0376-78922021000300014

2.Abdulrahim D, Sehmuz K. Impacto de los clavos intramedulares flexibles frente a los expuestos para osteosíntesis en fracturas pediátricas de antebrazo. Andes Pediatr. 2024;95(3):263-71. DOI: http://dx.doi.org/10.32641/andespediatr.v95i3.4926

3. Prieto R, Bestard G, Blanco J, Velázquez L, Pérez N. Tratamiento de las fracturas del antebrazo con placas de compresión dinámica. Rev Cub Ortop Traumatol. 2023 [acceso 17/10/2024];37(1). Disponible en: https://revortopedia.sld.cu/index.php/revortopedia/article/view/388

4. Russel TA. Classification of Diaphyseal fractures. En: Azar FM, Canale T, Beaty JH, editors. Campbell’s Operative Orthopaedics. 14 ed. Philadelphia, Pa: Elsevier; 2021. pp. 728-30.

5. World Medical Association. Declaration of Helsinki: ethical principles for medical research involving human subjects. JAMA. 2013;310(20):2191-4. DOI: https://doi.org/10.1001/jama.2013.281053

6.Álvarez A, Casanova C, Sánchez L, García Y. Fractura de la cúpula radial. Estudio de un año. AMC. 2001 [acceso 17/10/2024];5(4). Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S1025-02552001000400005

7. Morejón L, Mendizábal E, Delgado JA, Ledea OE, Fuentes G, López M, et al. Cementos óseos acrílicos: desarrollo de nuevas formulaciones bioactivas y con actividad terapéutica. Anales ACC. 2021 [acceso 17/10/2024];11(1). Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S2304-01062021000100010

8. Clembosky GA. Espaciador de cemento ortopédico como reemplazo de la cúpula radial. Rev Asoc Argent Ortop Traumatol. 2005 [acceso 17/10/2024];70(2):113-9. Disponible en: https://www.aaot.org.ar/revista/2005/n2_vol70/art2.pdf

9. Santos MT, Gónzález MJ, Soria M. Fractura de la cabeza del radio asociada a luxación aguda de la articulación radiocubital distal: fractura de Essex-Lopresti. Rev S And Traum Ort. 2002 [acceso 17/10/2024];22(1):47-52. Disponible en: https://www.elsevier.es/es-revista-revista-sociedad-andaluza-traumatologia-ortopedia-130-articulo-fractura-cabeza-del-radio-asociada-13035361

Published

2025-11-21

How to Cite

1.
Gómez Sarduy A, Mata Cuevas R, Morales Piñéiro S. Radial head replacement with a bone cement spacer. Revista Cubana de Ortopedia y Traumatologí­a [Internet]. 2025 Nov. 21 [cited 2025 Nov. 24];39. Available from: https://revortopedia.sld.cu/index.php/revortopedia/article/view/1020

Issue

Section

Presentación de casos