Double-plating for comminuted osteoporotic proximal humerus fracture
Keywords:
proximal humerus fracture, osteoporosis, double plate.Abstract
Introduction: Some proximal humerus fractures in elderly patients with osteoporosis are accompanied by medial metaphyseal comminution. Lateral Philos plate fixation is the most commonly used treatment. However, it cannot prevent loss of medial reduction and varus deformity, especially in cases of an unstable medial column.
Objective: To demonstrate that double-plating for proximal humerus fractures increases fixation stability.
Case report: We report the case of three female patients with Neer type 3 comminuted osteoporotic proximal humerus fractures, severe varus displacement, and medial column involvement. They were treated with double plating, and satisfactory functional and radiological results were achieved. Conclusions: Medial buttress plate fixation, in conjunction with the lateral Philos plate, is a viable option for the treatment of proximal humerus fractures in patients with an unstable medial column, varus deformity, and osteoporosis.
Downloads
References
He Y, Zhang Y, Wang Y , Zhou, Wang F. Biomechanical evaluation of a novel dual plate fixation method for proximal humeral fractures without medial support. J Orthop Surg Res. 2017;12:72. DOI: https://doi.org/10.1186/s13018-017-0573-4
Zhang Y, Wan L, Zhang L, Yan C, Wang G. Reduction and fixation of proximal humeral fracture with severe medial instability using a small locking plate. BMC Surg. 2021;21:387. DOI: https://doi.org/10.1186/s12893-021-01388-9
Mei Z, Lei W, Huang D, Ma W, Pan G, Ni L, et al. Locking compression plate combined with medial buttress plate for the treatment of osteoporotic comminuted proximal humerus fractures. Zhongguo Gu Shang. 2022;35(12):1193-6. DOI: https://doi.org/10.12200/j.issn.1003-0034.2022.12.016
Hung C, Yeh C, Wen P, Yeh W, Lin S. The effect of medial calcar support on proximal humeral fractures treated with locking plates. J Orthop Surg Res. 2022;17:467. DOI: https://doi.org/10.1186/s13018-022-03337-5
Rischen R, Köppe J, Stolberg J, Freistühler M, Faldum A, Raschke M, et al. Treatment reality of proximal humeral fractures in the elderly-trending variants of locking plate fixation in Germany. J Clin Med. 2023;12(4):1440. DOI: https://doi.org/10.3390/jcm12041440
Taskesen A, Göçer A, Uzel K, Yaradılmış Y. Effect of osteoporosis on proximal humerus fractures. Geriatr Orthop Surg Rehabil. 2020;11:1-6. DOI: https://doi.org/10.1177/2151459320985399
Warnhoff M, Jensen G, Hazra R, Theruvath P, Lill H, Ellwein A. Double plating - surgical technique and good clinical results in complex and highly unstable proximal humeral fractures. Injury. 2021;52(8):2285-91. DOI: https://doi.org/10.1016/j.injury.2021.05.047
Raithatha H, Patil V, Pai M, Shah S. Clinical and radiological outcome of dual plating for proximal humerus fractures. Cureus. 2023;15(1):e33570. DOI: https://doi.org/10.7759/cureus.33570
Michel P, Raschke M, Katthagen J, Schliemann B, Reißberg I, Riesenbeck O. Double plate for complex proximal humeral fractures: clinical and radiological results. J Clin Med. 2023;12(2):696. DOI: https://doi.org/10.3390/jcm12020696
Huang J, Liu W. Double plate technique and tendon fixation of long head of biceps brachii in treating Neer 3 to 4 partial fractures of proximal humerus. Zhongguo Gu Shang. 2022;35(12):1142-7. DOI: https://doi.org/10.12200/j.issn.1003-0034.2022.12.007
Wang F, Wang Y, Dong J, He Y, Li L, Liu F, et al. A novel surgical approach and technique and short-term clinical efficacy for the treatment of proximal humerus fractures with the combined use of medial anatomical locking plate fixation and minimally invasive lateral locking plate fixation. J Orthop Surg Res. 2021;16(1):29. DOI: https://doi.org/10.1186/s13018-020-02094-7
Park S, Ko Y. Medial buttress plating for humerus fractures with unstable medial column. J Orthop Trauma. 2019;33(9):e352-9. DOI: https://doi.org/10.1097/bot.0000000000001515
He Y, He J, Wang F, Zhou D, Wang Y, Wang B, et al. Application of additional medial plate in treatment of proximal humeral fractures with unstable medial column: a finite element study and clinical practice. Medicine (Baltimore). 2015;94(41):e1775. DOI: https://doi.org/10.1097%2FMD.0000000000001775
Choi S, Seo K, Kwon Y, Kang H, Cho CX, Rho J. Dual plate for comminuted proximal humerus fractures. Acta Orthop Belg. 2019 [acceso 26/05/2023];85(4):429-36. Disponible en: https://pubmed.ncbi.nlm.nih.gov/32374232/
Carbone S, Mezzoprete R, Papalia M, Arceri V, Carbone A, Gumina S. Radiographic patterns of osteoporotic proximal humerus fractures. Eur J Radiol. 2018;100:43-8. DOI: https://doi.org/10.1016/j.ejrad.2017.12.025
Bue M, Bright E, Thillemann T, Mosegaard S, Hansen T, Klebe T, et al. Osteoporosis does not affect bone mineral density change in the proximal humerus or the functional outcome after open reduction and internal fixation of unilateral displaced 3- or 4-part fractures at 12-month follow-up. J Shoulder Elbow Surg. 2023;32(2):292-301. DOI: https://doi.org/10.1016/j.jse.2022.07.008
Park S. Medial and lateral dual plate fixation for osteoporotic proximal humerus comminuted fracture: 2 case reports. J Korean Fract Soc. 2016;29(1):61-7. DOI: http://doi.org/10.12671/jkfs.2016.29.1.61